Stable Performance High Temperature Test Chamber Environmental Simulation Chamber
Product Details:
Place of Origin: | China |
Brand Name: | LIB |
Certification: | CE,ROHS |
Model Number: | T-100 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 Set |
---|---|
Packaging Details: | Wooden Cases Standard Export Package |
Delivery Time: | 5-14 Days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram,Paypal |
Supply Ability: | 410Sets |
Detail Information |
|||
Standard: | IEC-62660-2,IEC 62133,IEC 61960 | Temperature Range: | A : -20℃ ~ +150 ℃ B : -40℃ ~ +150 ℃ C: -70℃ ~ +150 ℃ |
---|---|---|---|
Cooling Rate: | 1 ℃ / Min | Heating Rate: | 3 ℃ / Min |
Power Supply: | 220V 50Hz / 380V 50Hz | Maximum Noise: | 65 DBA |
Highlight: | temperature and humidity test chamber,temp humidity chamber |
Product Description
Industrial High Temperature Controlled Environmental Simulation Chamber
►Introduction for Calibration Climatic Chamber Cold Temperature Aging Test Chamber Laboratory
Products you may use every day undergo this testing. Examples include: car parts, cell phones and other electronics, kitchen appliances, makeup, and hand soap. Some of those countless industries that rely on environmental testing include: medicine, pharma, food processing, food packaging, consumer goods and services, automotive, engineering, and construction.
►Application for Calibration Climatic Chamber Cold Temperature Aging Test Chamber Laboratory
Industrial High Temperature Controlled Environmental Simulation Chamber is also called environment testing machine, used to test various types of materials for their tolerances of heat, cold, dry, humidity. It is applied for quality inspection for all types of electronic products, electric appliance, and products from communication, instrument, automobile, plastic, metal, food, chemical, building materials, medical and aerospace industries.
►Advantages for Calibration Climatic Chamber Cold Temperature Aging Test Chamber Laboratory
1.Wide temperature/humidity ranges and volume selection
2.Temperature control and display unit
3.PID programmable color touch screen controller, network connection computer Multi-language interfaceUSB and Ethernet
4.A standard test hole, located at the left side of the work room
5.Water re-circulation system that reduced water use and a series of water pipes
6.Mechanical compression refrigeration system
7.Low temperature can cool down to -70℃
8.Long time to perform 85℃ 85%RH test
9.The Refrigerant can be replaced by R449A/R508B
10.CE mark
11.Long time to perform 85℃ 85%RH test
12.Temperature control and display unit Humidity control and display unit
►Main Parameter for Calibration Climatic Chamber Cold Temperature Aging Test Chamber Laboratory
Name | Industrial High Temperature Controlled Environmental Chamber | ||
Model | TH-100 | TH-500 | TH-800 |
Internal Dimension (mm) | 400*500*500 | 700*800*900 | 800*1000*1000 |
Overall Dimension (mm) |
860*1050*1620 |
1180*1350*2010 |
1280*1550*2110 |
Interior Volume | 100L | 500L | 800L |
Heat load | 1000W | ||
Temperature Range |
A : -20℃ ~ +150 ℃ B : -40℃ ~ +150 ℃ C: -70℃ ~ +150 ℃ |
||
Temperature Fluctuation | ± 0.5 ℃ | ||
Temperature Deviation | ± 2.0 ℃ | ||
Humidity Range |
20% ~ 98% RH |
||
Cooling Rate | 1 ℃ / min | ||
Heating Rate | 3 ℃ / min | ||
Heating Element | Nichrome heater | ||
Controller | Programmable color LCD touch screen controller | ||
Ethernet connection, PC Link | |||
Temperature Sensor | PTR Platinum Resistance PT100Ω/MV A-class, accuracy 0.001℃ | ||
Air Circulation | Centrifugal wind fan | ||
Safety Device |
Over-temperature Protection; Over-current Protection; Refrigerant High-Pressure Protection; Earth leakage Protection |
||
Exterior Material | Steel Plate with protective coating | ||
Thermal Insulation | Polyurethane foam and insulation cotton | ||
Observation Window | Interior lighting, double-layer thermo stability silicone rubber sealing | ||
Standard Confighration | 1 Cable hole (Φ 50,) with plug; 2 shelves | ||
Power Supply | 220V 50Hz / 380V 50Hz | ||
Maximum Noise | 65 dBA | ||
Environmental Conditional | 5℃~+35 ℃ ≤85% RH | ||
Refrigerant |
R404A, R23 |
||
Air Circulation |
Centrifugal wind fan |
►Main Details for Calibration Climatic Chamber Cold Temperature Aging Test Chamber Laboratory
![]() |
![]() |
1.Cable Hole A standard test hole, located at the left side of the work room, is provided with a sleeve inside to prevent moisture from entering the insulation layer. Equipped with flange. The standard inner hole diameter is 50mm. Soft silicone plug seal; Metal enclosure closed, beautiful designed. |
2.Temperature and Humiditty Sensor PT-100 Class A sensor, real-time accurate detection and display of temperature changes at 0.001 degrees. |
![]() |
![]() |
3.Workroom The internal material is 304 stainless steel, mirror surface, rust-proof to high and low temperature and moisture corrosion; Nice ruggedness and long life. |
4.Cooling System After the liquid refrigerant absorbs the heat of the cooled object in the evaporator, it is vaporized into low-temperature and low-pressure steam, sucked by the compressor, compressed into high-pressure high-temperature steam, discharged into the condenser, and radiated to the cooling medium in the condenser, condensed into a high-pressure liquid, throttling through a throttle valve into a low-pressure low-temperature refrigerant, and again entering the evaporator to absorb heat and vaporize, to achieve the purpose of cycle refrigeration. |
►Other Products
→Elevator Type Thermal Cycling Machine